Calibration is
performed by comparing the measuring lengths of calibration with the sample
deviation of the three-dimensional LEITZ PMM 866 measuring table along
direction (longitudinal).
Instrument in
calibration:
- Graduated
rulers
- Graduated rods
- Metric dipsticks
- Metric ribs
- Graduated crystal rulers
Measuring
range:
- Every 1000 mm up to 50
m
- Up to 250 mm (in crystal)
Measurement
uncertainty:
- [(3 + 2 L) + r]
µm
- (2.2 + 1 L) µm (in crystal)
The numeric
value of the nominal length in meters is indicated by L.
r is the
micron repeatability
and
depends on the quality of the lengths.
*
Measurement uncertainty corresponds to a confidence interval of approx.
95%.
La taratura viene
effettuata confrontando i tratti di misura oggetto della taratura con lo
spostamento campione della tavola di misura della tridimensionale LEITZ PMM 866
lungo la direzione X (longitudinale).
Strumento in taratura:- Righe graduate
- Aste graduate
- Stecche metriche
- Bindelle metriche
- Righe graduate in
cristallo
Campo di misura:- ogni a 1000 mm fino a 50
m
- fino a 250 mm (in
cristallo)
Incertezza di misura:- [(3 + 2 L) + r] µm
- (2,2 + 1 L) µm (in
cristallo)
Si indica con L il valore numerico
della lunghezza nominale espressa in metri.r è la ripetibilità in
micron e dipende dalla qualità dei tratti.
* L'incertezza di